On the structure of burner of heating furnace
时间:2021-12-18 浏览次数: 1118 作者: 加科

   The heating capacity of the burner of the heating furnace depends on the intensity of the flame (furnace temperature), the surface area of the furnace tube and the total heat transfer coefficient. The stronger the flame, the higher the furnace temperature, the greater the temperature difference between the furnace and the oil flow, and the greater the heat transfer: the larger the furnace tube area in contact with the flame and flue gas, the more heat transfer; The better the thermal conductivity of the furnace tube, the more reasonable the furnace structure and the more heat transfer.

   The burner structure of heating furnace is mainly composed of the following five systems:

   Air supply system: the function of the air supply system is to send air with a certain wind speed and air volume into the combustion chamber. Its main components include: shell, fan motor, fan impeller, air gun fire pipe, damper controller, damper baffle, cam adjusting mechanism and diffuser.

   2. Ignition system: the function of the ignition system of the burner of the heating furnace is to ignite the mixture of air and fuel

   There are: ignition transformer, ignition electrode, electric fire high-voltage cable.

   3. Monitoring system: the function of the monitoring system is to ensure the safe and stable operation of the burner, and its main components are flame

   Monitors, pressure monitors, temperature monitors, etc.

   4. Fuel system: the function of burner fuel system of heating furnace is to ensure the fuel required for burner combustion. The fuel system of fuel burner mainly includes: oil pipe and joint, oil pump, solenoid valve, nozzle and heavy oil preheater. As long as the gas burner has filter, pressure regulator, solenoid valve group, ignition solenoid valve group and fuel butterfly valve.

   5. Electric control system: the electric control system is the command center and contact center of the above systems. The main control element is the program controller. Different program controllers are equipped for different sulfur recovery burners. The main difference is that the step time of each program is different.


咨询热线
  • 座机:0531-83659330
  • 传真:0531-83382689
  • 邮箱:admin@gacoch.com
  • 总部地址:济南章丘区大友中心1号楼
最新动态
加科时代 | 天籁之音,环保之魂
加科时代 | 天籁之音,环保之魂

加科时代|天籁之音,环保之魂引言近日,江西天沅环保集团旗下潍坊昌乐大明生物科技有限公司600万大卡导热油锅炉煤气、···

+MORE
272024-04
加科装备携手国家电投打造绿色新动能
加科装备携手国家电投打造绿色新动能

国家电力投资集团有限公司(简称“国家电投”)是中央直接管理的特大型国有重要骨干企业,肩负保障国家能源安全的重要···

+MORE
102024-01
联系我们

24小时竭诚为您服务

13210550198(微信同号)

地址:山东济南章丘区大友中心1号楼

邮箱:admin@gacoch.com

电话
0531-83659330
微信
微信二位码
留言
返回顶部
加科(山东)智能装备有限公司 备案号:鲁ICP备17025986号-5
首页
产品
咨询
应用
服务